{"id":8998,"date":"2026-11-16T14:37:15","date_gmt":"2026-11-16T14:37:15","guid":{"rendered":"https:\/\/www.buildsoft.eu\/eurocode-2-deuxieme-generation-g2-ce-qui-change-pour-les-ingenieurs-structure\/"},"modified":"2026-11-17T08:49:45","modified_gmt":"2026-11-17T08:49:45","slug":"eurocode-2-deuxieme-generation-g2-ce-qui-change-pour-les-ingenieurs-structure","status":"publish","type":"post","link":"https:\/\/www.buildsoft.eu\/fr\/eurocode-2-deuxieme-generation-g2-ce-qui-change-pour-les-ingenieurs-structure\/","title":{"rendered":"Eurocode 2 deuxi\u00e8me g\u00e9n\u00e9ration (G2) : ce qui change pour les ing\u00e9nieurs structure"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">En un coup d&rsquo;\u0153il<\/h2>\n\n<p>Le nouvel Eurocode 2, la deuxi\u00e8me g\u00e9n\u00e9ration de l&rsquo;EN 1992-1-1, remplace la version de 2004. Le CEN pr\u00e9voit de retirer la premi\u00e8re g\u00e9n\u00e9ration d&rsquo;ici le 30 mars 2028. Cette s\u00e9rie compare les anciennes et les nouvelles r\u00e8gles sujet par sujet, avec le m\u00eame exemple de calcul dans chaque article : une section rectangulaire de 300\u00d7400 mm en C25\/30. Elle s&rsquo;adresse aux ing\u00e9nieurs qui dimensionnent des structures en b\u00e9ton et veulent savoir ce qui change dans leurs calculs.<\/p>\n\n<p><strong>Liste non exhaustive:<\/strong> cette s\u00e9rie ne couvre pas toutes les diff\u00e9rences entre G1 et G2. Elle retient les modifications les plus importantes pour l&rsquo;analyse et le dimensionnement des structures et renvoie le reste \u00e0 la norme elle-m\u00eame.<\/p>\n\n<h2 class=\"wp-block-heading\">G1 et G2 expliqu\u00e9s<\/h2>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>Nom court<\/th><th>Norme<\/th><th>Statut<\/th><\/tr><tr><td>G1<\/td><td>EN 1992-1-1:2004, la premi\u00e8re g\u00e9n\u00e9ration<\/td><td>Le code avec lequel vous dimensionnez aujourd&rsquo;hui<\/td><\/tr><tr><td>G2<\/td><td>EN 1992-1-1:2023, la deuxi\u00e8me g\u00e9n\u00e9ration<\/td><td>Ne peut \u00eatre appliqu\u00e9e dans un pays qu&rsquo;apr\u00e8s la publication de son Annexe Nationale<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p>G1 et G2 sont des abr\u00e9viations propres \u00e0 cette s\u00e9rie. Le CEN parle lui-m\u00eame d&rsquo;Eurocodes de premi\u00e8re et de deuxi\u00e8me g\u00e9n\u00e9ration. Les r\u00e8gles changent, mais la num\u00e9rotation des articles aussi : l&rsquo;effort tranchant sans armatures d&rsquo;effort tranchant est trait\u00e9 en 6.2.2 dans G1 et en 8.2.2 dans G2 ; chaque article donne donc les deux r\u00e9f\u00e9rences.<\/p>\n\n<h2 class=\"wp-block-heading\">Quand le nouvel Eurocode 2 s&rsquo;applique<\/h2>\n\n<p>Le CEN\/TC 250 a fix\u00e9 trois dates dans son courrier sur le calendrier du 21 septembre 2023 :<\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>Date<\/th><th>Jalon<\/th><th>Ce que cela signifie<\/th><\/tr><tr><td>Au plus tard le 30 mars 2026<\/td><td>Date of availability (DAV), date de disponibilit\u00e9<\/td><td>Les textes finaux parviennent aux organismes nationaux de normalisation<\/td><\/tr><tr><td>30 septembre 2027<\/td><td>Date of publication (DoP), date de publication<\/td><td>Date limite pour que chaque pays publie la norme au niveau national<\/td><\/tr><tr><td>30 mars 2028<\/td><td>Date of withdrawal (DoW), date de retrait<\/td><td>Les normes nationales contradictoires, dont la premi\u00e8re g\u00e9n\u00e9ration, doivent \u00eatre retir\u00e9es<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p>Les pays peuvent publier plus t\u00f4t. En Belgique, Buildwise indique que l&rsquo;EN 1992-1-1:2023 n&rsquo;a pas encore le statut de norme belge et ne pourra \u00eatre appliqu\u00e9e qu&rsquo;apr\u00e8s la publication de l&rsquo;Annexe Nationale belge. En France, la publication nationale des normes NF EN et de leurs Annexes Nationales rel\u00e8ve de l&rsquo;AFNOR. V\u00e9rifiez la situation actuelle aupr\u00e8s de votre organisme national de normalisation avant de d\u00e9marrer un projet selon G2.<\/p>\n\n<h2 class=\"wp-block-heading\">Les 11 sujets de cette s\u00e9rie<\/h2>\n\n<p>Nous commen\u00e7ons par les points qui modifient un r\u00e9sultat de calcul ou un d\u00e9tail sur chantier :<\/p>\n\n<figure class=\"wp-block-table\"><table><tbody><tr><th>#<\/th><th>Sujet<\/th><th>G1 \u2192 G2 article<\/th><\/tr><tr><td>1<\/td><td>Moduel d&rsquo;elasticit\u00e9 E_cm<\/td><td>3.1.3 \u2192 5.1.4<\/td><\/tr><tr><td>2<\/td><td>R\u00e9sistance de calcul et diagramme contraintes-d\u00e9formations<\/td><td>3.1.6\u20133.1.7, 6.1 \u2192 5.1.6, 8.1.2<\/td><\/tr><tr><td>3<\/td><td>Fluage et retrait<\/td><td>3.1.4, Annex B \u2192 5.1.5, Annex B<\/td><\/tr><tr><td>4<\/td><td>Durabilit\u00e9 et enrobage<\/td><td>4.4 \u2192 6.3\u20136.5<\/td><\/tr><tr><td>5<\/td><td>Effort tranchant sans armatures d&rsquo;effort tranchant<\/td><td>6.2.2 \u2192 8.2.2<\/td><\/tr><tr><td>6<\/td><td>Effort tranchant avec armatures d&rsquo;effort tranchant<\/td><td>6.2.3 \u2192 8.2.3<\/td><\/tr><tr><td>7<\/td><td>Torsion<\/td><td>6.3 \u2192 8.3<\/td><\/tr><tr><td>8<\/td><td>Poin\u00e7onnement<\/td><td>6.4 \u2192 8.4<\/td><\/tr><tr><td>9<\/td><td>Ma\u00eetrise de la fissuration<\/td><td>7.3 \u2192 9.2<\/td><\/tr><tr><td>10<\/td><td>Ma\u00eetrise des fl\u00e8ches<\/td><td>7.4 \u2192 9.3<\/td><\/tr><tr><td>11<\/td><td>Ancrage et recouvrements<\/td><td>8.4, 8.7 \u2192 11.4, 11.5<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<h2 class=\"wp-block-heading\">Comment chaque article est construit<\/h2>\n\n<p>Chaque article comporte les m\u00eames quatre parties, pour que vous trouviez vite ce que vous cherchez :<\/p>\n\n<ol class=\"wp-block-list\">\n<li><strong>En un coup d&rsquo;\u0153il:<\/strong> la diff\u00e9rence en une ou deux phrases, avec son ampleur en pourcentage.<\/li>\n\n\n\n<li><strong>G1 et G2 c\u00f4te \u00e0 c\u00f4te:<\/strong> les r\u00e8gles avec les num\u00e9ros d&rsquo;articles, un symbole par ligne.<\/li>\n\n\n\n<li><strong>Exemple de calcul:<\/strong> la m\u00eame section de 300\u00d7400 mm en C25\/30 dans les deux codes, afin que les r\u00e9sultats soient comparables d&rsquo;un article \u00e0 l&rsquo;autre.<\/li>\n\n\n\n<li><strong>Ce que cela signifie en pratique:<\/strong> l&rsquo;effet sur les fl\u00e8ches, les armatures ou les dispositions constructives.<\/li>\n<\/ol>\n\n<h2 class=\"wp-block-heading\">Sources et avertissement<\/h2>\n\n<p>Calendrier et statut tels que lus le 9 novembre 2026 : le courrier du CEN\/TC 250 sur le calendrier. Les r\u00e8gles et valeurs suivent l&rsquo;EN 1992-1-1:2004 et l&rsquo;EN 1992-1-1:2023. Les Annexes Nationales peuvent fixer d&rsquo;autres valeurs ; v\u00e9rifiez donc l&rsquo;annexe de votre pays avant d&rsquo;utiliser une valeur dans un dimensionnement.<\/p>\n\n<p>Cette s\u00e9rie n&rsquo;est pas une liste compl\u00e8te des modifications entre l&rsquo;EN 1992-1-1:2004 et l&rsquo;EN 1992-1-1:2023. Elle couvre les plus importantes pour l&rsquo;analyse et le dimensionnement des structures. Pour les exigences compl\u00e8tes, reportez-vous toujours \u00e0 la norme et \u00e0 votre Annexe Nationale.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>En un coup d&rsquo;\u0153il Le nouvel Eurocode 2, la deuxi\u00e8me g\u00e9n\u00e9ration de l&rsquo;EN 1992-1-1, remplace la version de 2004. Le [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":8944,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"_jet_sm_ready_style":"","_jet_sm_style":"","_jet_sm_controls_values":"","_jet_sm_fonts_collection":"","_jet_sm_fonts_links":"","footnotes":""},"categories":[155,139,154],"tags":[],"class_list":["post-8998","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-beton-fr","category-eurocode-fr","category-eurocode-2-fr"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Eurocode 2 deuxi\u00e8me g\u00e9n\u00e9ration (G2) : ce qui change pour les ing\u00e9nieurs structure | BuildSoft<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.buildsoft.eu\/fr\/eurocode-2-deuxieme-generation-g2-ce-qui-change-pour-les-ingenieurs-structure\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Eurocode 2 deuxi\u00e8me g\u00e9n\u00e9ration (G2) : ce qui change pour les ing\u00e9nieurs structure | BuildSoft\" \/>\n<meta property=\"og:description\" content=\"En un coup d&rsquo;\u0153il Le nouvel Eurocode 2, la deuxi\u00e8me g\u00e9n\u00e9ration de l&rsquo;EN 1992-1-1, remplace la version de 2004. Le [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.buildsoft.eu\/fr\/eurocode-2-deuxieme-generation-g2-ce-qui-change-pour-les-ingenieurs-structure\/\" \/>\n<meta property=\"og:site_name\" content=\"BuildSoft\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/StructuralAnalysisSoftware\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-16T14:37:15+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-17T08:49:45+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.buildsoft.eu\/wp-content\/uploads\/2026\/11\/blog_EC2_overview.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"BuildSoft\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"BuildSoft\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.buildsoft.eu\/fr\/eurocode-2-deuxieme-generation-g2-ce-qui-change-pour-les-ingenieurs-structure\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.buildsoft.eu\/fr\/eurocode-2-deuxieme-generation-g2-ce-qui-change-pour-les-ingenieurs-structure\/\"},\"author\":{\"name\":\"BuildSoft\",\"@id\":\"https:\/\/www.buildsoft.eu\/fr\/#\/schema\/person\/3cb64b87bfc60897ac69e2912fc91390\"},\"headline\":\"Eurocode 2 deuxi\u00e8me g\u00e9n\u00e9ration (G2) : ce qui change pour les ing\u00e9nieurs structure\",\"datePublished\":\"2026-11-16T14:37:15+00:00\",\"dateModified\":\"2026-11-17T08:49:45+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.buildsoft.eu\/fr\/eurocode-2-deuxieme-generation-g2-ce-qui-change-pour-les-ingenieurs-structure\/\"},\"wordCount\":700,\"publisher\":{\"@id\":\"https:\/\/www.buildsoft.eu\/fr\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.buildsoft.eu\/fr\/eurocode-2-deuxieme-generation-g2-ce-qui-change-pour-les-ingenieurs-structure\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.buildsoft.eu\/wp-content\/uploads\/2026\/11\/blog_EC2_overview.webp\",\"articleSection\":[\"B\u00e9ton\",\"Eurocode\",\"Eurocode 2\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.buildsoft.eu\/fr\/eurocode-2-deuxieme-generation-g2-ce-qui-change-pour-les-ingenieurs-structure\/\",\"url\":\"https:\/\/www.buildsoft.eu\/fr\/eurocode-2-deuxieme-generation-g2-ce-qui-change-pour-les-ingenieurs-structure\/\",\"name\":\"Eurocode 2 deuxi\u00e8me g\u00e9n\u00e9ration (G2) : ce qui change pour les ing\u00e9nieurs structure | BuildSoft\",\"isPartOf\":{\"@id\":\"https:\/\/www.buildsoft.eu\/fr\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.buildsoft.eu\/fr\/eurocode-2-deuxieme-generation-g2-ce-qui-change-pour-les-ingenieurs-structure\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.buildsoft.eu\/fr\/eurocode-2-deuxieme-generation-g2-ce-qui-change-pour-les-ingenieurs-structure\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.buildsoft.eu\/wp-content\/uploads\/2026\/11\/blog_EC2_overview.webp\",\"datePublished\":\"2026-11-16T14:37:15+00:00\",\"dateModified\":\"2026-11-17T08:49:45+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.buildsoft.eu\/fr\/eurocode-2-deuxieme-generation-g2-ce-qui-change-pour-les-ingenieurs-structure\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.buildsoft.eu\/fr\/eurocode-2-deuxieme-generation-g2-ce-qui-change-pour-les-ingenieurs-structure\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.buildsoft.eu\/fr\/eurocode-2-deuxieme-generation-g2-ce-qui-change-pour-les-ingenieurs-structure\/#primaryimage\",\"url\":\"https:\/\/www.buildsoft.eu\/wp-content\/uploads\/2026\/11\/blog_EC2_overview.webp\",\"contentUrl\":\"https:\/\/www.buildsoft.eu\/wp-content\/uploads\/2026\/11\/blog_EC2_overview.webp\",\"width\":1200,\"height\":800},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.buildsoft.eu\/fr\/eurocode-2-deuxieme-generation-g2-ce-qui-change-pour-les-ingenieurs-structure\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.buildsoft.eu\/fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Eurocode 2 deuxi\u00e8me g\u00e9n\u00e9ration (G2) : ce qui change pour les ing\u00e9nieurs structure\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.buildsoft.eu\/fr\/#website\",\"url\":\"https:\/\/www.buildsoft.eu\/fr\/\",\"name\":\"BuildSoft\",\"description\":\"Structural engineering software\",\"publisher\":{\"@id\":\"https:\/\/www.buildsoft.eu\/fr\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.buildsoft.eu\/fr\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.buildsoft.eu\/fr\/#organization\",\"name\":\"BuildSoft\",\"url\":\"https:\/\/www.buildsoft.eu\/fr\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.buildsoft.eu\/fr\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.buildsoft.eu\/wp-content\/uploads\/2024\/05\/buildsoft-logo-structurally-loved-big-e1717406977624.png\",\"contentUrl\":\"https:\/\/www.buildsoft.eu\/wp-content\/uploads\/2024\/05\/buildsoft-logo-structurally-loved-big-e1717406977624.png\",\"width\":9732,\"height\":3584,\"caption\":\"BuildSoft\"},\"image\":{\"@id\":\"https:\/\/www.buildsoft.eu\/fr\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/StructuralAnalysisSoftware\",\"https:\/\/www.linkedin.com\/company\/buildsoft\",\"https:\/\/www.youtube.com\/channel\/UCnGxgfJrvsL9ZEje-BvrdSg\",\"https:\/\/www.instagram.com\/buildsoft.eu\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.buildsoft.eu\/fr\/#\/schema\/person\/3cb64b87bfc60897ac69e2912fc91390\",\"name\":\"BuildSoft\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.buildsoft.eu\/fr\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/81e6ffdb158fef1cf85544cab007fa6f?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/81e6ffdb158fef1cf85544cab007fa6f?s=96&d=mm&r=g\",\"caption\":\"BuildSoft\"},\"sameAs\":[\"https:\/\/structural-engineering-software.com\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Eurocode 2 deuxi\u00e8me g\u00e9n\u00e9ration (G2) : ce qui change pour les ing\u00e9nieurs structure | BuildSoft","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.buildsoft.eu\/fr\/eurocode-2-deuxieme-generation-g2-ce-qui-change-pour-les-ingenieurs-structure\/","og_locale":"fr_FR","og_type":"article","og_title":"Eurocode 2 deuxi\u00e8me g\u00e9n\u00e9ration (G2) : ce qui change pour les ing\u00e9nieurs structure | BuildSoft","og_description":"En un coup d&rsquo;\u0153il Le nouvel Eurocode 2, la deuxi\u00e8me g\u00e9n\u00e9ration de l&rsquo;EN 1992-1-1, remplace la version de 2004. Le [&hellip;]","og_url":"https:\/\/www.buildsoft.eu\/fr\/eurocode-2-deuxieme-generation-g2-ce-qui-change-pour-les-ingenieurs-structure\/","og_site_name":"BuildSoft","article_publisher":"https:\/\/www.facebook.com\/StructuralAnalysisSoftware","article_published_time":"2026-11-16T14:37:15+00:00","article_modified_time":"2026-11-17T08:49:45+00:00","og_image":[{"width":1200,"height":800,"url":"https:\/\/www.buildsoft.eu\/wp-content\/uploads\/2026\/11\/blog_EC2_overview.webp","type":"image\/webp"}],"author":"BuildSoft","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"BuildSoft","Dur\u00e9e de lecture estim\u00e9e":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.buildsoft.eu\/fr\/eurocode-2-deuxieme-generation-g2-ce-qui-change-pour-les-ingenieurs-structure\/#article","isPartOf":{"@id":"https:\/\/www.buildsoft.eu\/fr\/eurocode-2-deuxieme-generation-g2-ce-qui-change-pour-les-ingenieurs-structure\/"},"author":{"name":"BuildSoft","@id":"https:\/\/www.buildsoft.eu\/fr\/#\/schema\/person\/3cb64b87bfc60897ac69e2912fc91390"},"headline":"Eurocode 2 deuxi\u00e8me g\u00e9n\u00e9ration (G2) : ce qui change pour les ing\u00e9nieurs structure","datePublished":"2026-11-16T14:37:15+00:00","dateModified":"2026-11-17T08:49:45+00:00","mainEntityOfPage":{"@id":"https:\/\/www.buildsoft.eu\/fr\/eurocode-2-deuxieme-generation-g2-ce-qui-change-pour-les-ingenieurs-structure\/"},"wordCount":700,"publisher":{"@id":"https:\/\/www.buildsoft.eu\/fr\/#organization"},"image":{"@id":"https:\/\/www.buildsoft.eu\/fr\/eurocode-2-deuxieme-generation-g2-ce-qui-change-pour-les-ingenieurs-structure\/#primaryimage"},"thumbnailUrl":"https:\/\/www.buildsoft.eu\/wp-content\/uploads\/2026\/11\/blog_EC2_overview.webp","articleSection":["B\u00e9ton","Eurocode","Eurocode 2"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/www.buildsoft.eu\/fr\/eurocode-2-deuxieme-generation-g2-ce-qui-change-pour-les-ingenieurs-structure\/","url":"https:\/\/www.buildsoft.eu\/fr\/eurocode-2-deuxieme-generation-g2-ce-qui-change-pour-les-ingenieurs-structure\/","name":"Eurocode 2 deuxi\u00e8me g\u00e9n\u00e9ration (G2) : ce qui change pour les ing\u00e9nieurs structure | BuildSoft","isPartOf":{"@id":"https:\/\/www.buildsoft.eu\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.buildsoft.eu\/fr\/eurocode-2-deuxieme-generation-g2-ce-qui-change-pour-les-ingenieurs-structure\/#primaryimage"},"image":{"@id":"https:\/\/www.buildsoft.eu\/fr\/eurocode-2-deuxieme-generation-g2-ce-qui-change-pour-les-ingenieurs-structure\/#primaryimage"},"thumbnailUrl":"https:\/\/www.buildsoft.eu\/wp-content\/uploads\/2026\/11\/blog_EC2_overview.webp","datePublished":"2026-11-16T14:37:15+00:00","dateModified":"2026-11-17T08:49:45+00:00","breadcrumb":{"@id":"https:\/\/www.buildsoft.eu\/fr\/eurocode-2-deuxieme-generation-g2-ce-qui-change-pour-les-ingenieurs-structure\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.buildsoft.eu\/fr\/eurocode-2-deuxieme-generation-g2-ce-qui-change-pour-les-ingenieurs-structure\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.buildsoft.eu\/fr\/eurocode-2-deuxieme-generation-g2-ce-qui-change-pour-les-ingenieurs-structure\/#primaryimage","url":"https:\/\/www.buildsoft.eu\/wp-content\/uploads\/2026\/11\/blog_EC2_overview.webp","contentUrl":"https:\/\/www.buildsoft.eu\/wp-content\/uploads\/2026\/11\/blog_EC2_overview.webp","width":1200,"height":800},{"@type":"BreadcrumbList","@id":"https:\/\/www.buildsoft.eu\/fr\/eurocode-2-deuxieme-generation-g2-ce-qui-change-pour-les-ingenieurs-structure\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.buildsoft.eu\/fr\/"},{"@type":"ListItem","position":2,"name":"Eurocode 2 deuxi\u00e8me g\u00e9n\u00e9ration (G2) : ce qui change pour les ing\u00e9nieurs structure"}]},{"@type":"WebSite","@id":"https:\/\/www.buildsoft.eu\/fr\/#website","url":"https:\/\/www.buildsoft.eu\/fr\/","name":"BuildSoft","description":"Structural engineering software","publisher":{"@id":"https:\/\/www.buildsoft.eu\/fr\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.buildsoft.eu\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.buildsoft.eu\/fr\/#organization","name":"BuildSoft","url":"https:\/\/www.buildsoft.eu\/fr\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.buildsoft.eu\/fr\/#\/schema\/logo\/image\/","url":"https:\/\/www.buildsoft.eu\/wp-content\/uploads\/2024\/05\/buildsoft-logo-structurally-loved-big-e1717406977624.png","contentUrl":"https:\/\/www.buildsoft.eu\/wp-content\/uploads\/2024\/05\/buildsoft-logo-structurally-loved-big-e1717406977624.png","width":9732,"height":3584,"caption":"BuildSoft"},"image":{"@id":"https:\/\/www.buildsoft.eu\/fr\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/StructuralAnalysisSoftware","https:\/\/www.linkedin.com\/company\/buildsoft","https:\/\/www.youtube.com\/channel\/UCnGxgfJrvsL9ZEje-BvrdSg","https:\/\/www.instagram.com\/buildsoft.eu"]},{"@type":"Person","@id":"https:\/\/www.buildsoft.eu\/fr\/#\/schema\/person\/3cb64b87bfc60897ac69e2912fc91390","name":"BuildSoft","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.buildsoft.eu\/fr\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/81e6ffdb158fef1cf85544cab007fa6f?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/81e6ffdb158fef1cf85544cab007fa6f?s=96&d=mm&r=g","caption":"BuildSoft"},"sameAs":["https:\/\/structural-engineering-software.com"]}]}},"uagb_featured_image_src":{"full":["https:\/\/www.buildsoft.eu\/wp-content\/uploads\/2026\/11\/blog_EC2_overview.webp",1200,800,false],"thumbnail":["https:\/\/www.buildsoft.eu\/wp-content\/uploads\/2026\/11\/blog_EC2_overview-150x150.webp",150,150,true],"medium":["https:\/\/www.buildsoft.eu\/wp-content\/uploads\/2026\/11\/blog_EC2_overview-300x200.webp",300,200,true],"medium_large":["https:\/\/www.buildsoft.eu\/wp-content\/uploads\/2026\/11\/blog_EC2_overview-768x512.webp",768,512,true],"large":["https:\/\/www.buildsoft.eu\/wp-content\/uploads\/2026\/11\/blog_EC2_overview-1024x683.webp",1024,683,true],"1536x1536":["https:\/\/www.buildsoft.eu\/wp-content\/uploads\/2026\/11\/blog_EC2_overview.webp",1200,800,false],"2048x2048":["https:\/\/www.buildsoft.eu\/wp-content\/uploads\/2026\/11\/blog_EC2_overview.webp",1200,800,false]},"uagb_author_info":{"display_name":"BuildSoft","author_link":"https:\/\/www.buildsoft.eu\/fr\/author\/buildsoft\/"},"uagb_comment_info":0,"uagb_excerpt":"En un coup d&rsquo;\u0153il Le nouvel Eurocode 2, la deuxi\u00e8me g\u00e9n\u00e9ration de l&rsquo;EN 1992-1-1, remplace la version de 2004. Le [&hellip;]","_links":{"self":[{"href":"https:\/\/www.buildsoft.eu\/fr\/wp-json\/wp\/v2\/posts\/8998","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.buildsoft.eu\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.buildsoft.eu\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.buildsoft.eu\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.buildsoft.eu\/fr\/wp-json\/wp\/v2\/comments?post=8998"}],"version-history":[{"count":1,"href":"https:\/\/www.buildsoft.eu\/fr\/wp-json\/wp\/v2\/posts\/8998\/revisions"}],"predecessor-version":[{"id":8999,"href":"https:\/\/www.buildsoft.eu\/fr\/wp-json\/wp\/v2\/posts\/8998\/revisions\/8999"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.buildsoft.eu\/fr\/wp-json\/wp\/v2\/media\/8944"}],"wp:attachment":[{"href":"https:\/\/www.buildsoft.eu\/fr\/wp-json\/wp\/v2\/media?parent=8998"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.buildsoft.eu\/fr\/wp-json\/wp\/v2\/categories?post=8998"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.buildsoft.eu\/fr\/wp-json\/wp\/v2\/tags?post=8998"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}