At a glance
The new Eurocode 2 (G2, EN 1992-1-1:2023) predicts more long-term creep for a C25/30: the creep coefficient after 50 years rises from 2.69 to 2.90 (+7.8%). The model is rebuilt: G2 splits creep into a basic and a drying part. G2 gives less creep in the first years and more after decades. The effective modulus for long-term deflection changes too: G1 uses
, G2 uses
. With the lower
and the higher creep, it drops by 4%.
G1 vs G2 side by side
| Symbol | Rule | G1 (2004) | G2 (2023) |
|---|---|---|---|
| Creep coefficient | notional creep & time creep (B.1) | basic + drying creep (B.5) | |
| Quick method | Figure 3.1, final value | Table 5.2, value after 50 years | |
| Notional size | Unchanged | ||
| Cement class on age at loading | Unchanged, (B.9) | Unchanged, (B.17) | |
| Limit for linear creep | non-linear above, (3.7) | non-linear from 0.4 to 0.6, (B.19) | |
| Tangent modulus for creep strain | 3.1.4(2) | Unchanged 5.1.5(1) | |
| Effective modulus for long-term deflection | (7.20) | (9.1) |
Worked example: C25/30, 300×400 mm
Assumptions: indoor,
, cement class N, loaded at
, value after 50 years (18 250 days), all faces exposed:
| G1 (2004) | G2 (2023) | |
|---|---|---|
| +7.8% | ||
| -3.8% | ||
| -3.8% |
G2 gives less creep in the first years (−6.4% after 1 year, −0.2% after 10 years) and more after decades (+11.6% after 100 years), because basic creep keeps growing with ln(t).
What it means in practice
- Long-term deflection: the effective modulus of this uncracked C25/30 member is 4% lower, so the long-term deflection under sustained load is about 4% higher. The formula looks unchanged, but G1 uses E_cm in (7.20) and G2 uses 1.05·E_cm in (9.1).
- Time dependence: G1 gives a final value, G2 a value after 50 years that keeps growing slowly. For a design life over 50 years, use Annex B.
- High stress: non-linear creep now starts at 0.40 f_cm(t_0) instead of 0.45 f_ck(t_0), which matters for highly stressed members such as prestressed precast elements.
Try it in Diamonds
Diamonds is BuildSoft’s 3D FEM structural analysis software, and you can learn it in under an hour. Start your free 30-day trial at buildsoft.eu.
Sources
Sources: EN 1992-1-1:2004, 3.1.4, 7.4.3(5) and Annex B (B.1 to B.10); EN 1992-1-1:2023, 5.1.5, 9.1(4), Table 5.2 and Annex B (B.5 to B.21). Figures calculated by hand from the formulas for A_c = 120 000 mm², u = 1 400 mm.