Eurocode 2 second generation: shear without shear reinforcement

At a glance

For a typical beam, EN 1992-1-1:2023 (G2) gives 9% less shear resistance without shear reinforcement than EN 1992-1-1:2004 (G1), and the gap grows with member depth. Very lightly reinforced members get more.

  • New size effect. The factor k = 1 + \sqrt{(200/d)} is gone. G2 uses d_{dg}/d, where d_{dg} (max 40 mm) depends on the aggregate size, so the aggregate you specify now enters the calculation.
  • Stress-based format. G2 checks a shear stress \tau_{Rd,c} over a lever arm z = 0,9d, with \gamma_V = 1.4 instead of \gamma_C = 1.5.
  • New minimum. v_{min} (a function of f_{ck} and k) is replaced by \tau_{Rdc,min}, which also depends on f_{yd} and d_{dg}/d. In our example it raises the minimum by 26%.
  • d > 500 mm. Linear members in statically determinate structures always need minimum shear reinforcement, even when the calculation says none is required.

On our reference beam (C25/30, 300 × 400 mm): G1 gives 62,4 kN and G2 gives 56,6 kN.

G1 vs G2 side by side

AspectG1: EN 1992-1-1:2004, 6.2.2G2: EN 1992-1-1:2023, 8.2.2
Design basisForce (6.2.a) Stress (8.27)
Stressv_{Rd,c}= \frac {0.18} {\gamma_C} \cdot k\cdot (100 \rho_l f_{ck})^{1/3} + k_1 \cdot \sigma_{cp}\tau_{Rd,c} =\frac { 0.66}{\gamma_V} · (100 \cdot  \rho_l  \cdot f_{ck}  \cdot d_{dg}/d)^{1/3}
ForceV_{Rd,c} = v_{Rd,c} \cdot b_w \cdot dV_{Rd,c}  = \tau_{Rd,c}  \cdot b_w  \cdot z
z = 0.9d
Partial factor\gamma_C = 1.5\gamma_V = 1.4
Size effectk = 1 + \sqrt{(200/d)} \le 2,0d_{dg}/d
d_{dg} = 16mm + D_{lower} \le 40mm
Reinforcement ratio\rho_l = \frac{A{sl}}{b_w \dot d} \le 0,02\rho_l = \frac{A{sl}}{b_w \dot d}
Minimumv_{min} = 0.035 \cdot k^{3/2} \cdot f_{ck}^{1/2}
(6.3N)
\tau_{Rdc,min} = 11/\gamma_V \cdot \sqrt {f_{ck}/f_{yd} \cdot d_{dg}/d)
(8.20)
When no calculation is neededNot defined\tau_{Ed} \le \tau_{Rdc,min}
(8.2.1(1)a)
Minimum shear reinforcementAlways required (6.2.1(4), 9.2.2), except in slabs and members of minor importanceMay be required (Clause 12); always for linear members in statically determinate structures with d > 500 mm (8.2.1(2))

Worked example

Our reference beam gives V_{Rd,c} = 62.4 kN in G1 and 56.6 kN in G2 (−9.3%), while the minimum resistance goes up by 26%.

Input: b=b_w = 300 mm, h = 400 mm, d = 350 mm, f_{ck} = 25 MPa (C25/30), 3Ø20 tension steel (A_{sl} = 942 mm^2, \rho_l = 0.90\%), B500 (f_{yd} = 435 MPa), D_{lower} = 16 mm, \gamma_C = 1.5 \gamma_V = 1.4 .

G1 (6.2.2)G2 (8.2.2)\Delta
k = 1 + \sqrt{(200/350)} = 1.756d_{dg} = 16mm + 16 = 32 mm
d_{dg}/d = 0.0914
v_{Rd,c}=\frac{0.18}{1.5} \cdot 1.756  \cdot (100  \cdot 0.00897 \cdot 25)^{1/3} = 0.594\tau_{Rd,c} =\frac{0.66}{1.4} \cdot (100 \cdot 0.00897 \cdot 25 \cdot 0.0914)^{1/3}= 0.599
v_{min} = 0.035 \cdot 1.756^{1.5} \cdot  \sqrt{25} = 0.407\tau_{Rdc,min} = 11/1.4 \cdot \sqrt{25/435 \cdot 0.0914} = 0.570
b_w \cdot  d = 300 \cdot 350 =  105 000 mm^2b_w \cdot  z  = 300 \cdot 315 = 94 500 mm^2
V_{Rd,c} = 62.4 kNV_{Rd,c} =56.6 kN-9,3%
V_{Rd,c,min} = 0.407 \cdot 105 000 = 42.8 kNV_{Rd,c,min}= 0.57 \cdot 94 500 = 53.8 kN+26%
V_{Rd,c} = 62.4 kNV_{Rd,c} = 56.6 kN-9.3%

The two stresses are almost the same (0,594 vs 0,599 MPa). The difference comes from the lever arm: G2 multiplies the stress by 0,9d, G1 by d.

What it means in practice

For a typical beam you can expect 5 to 10% less shear resistance without shear reinforcement under G2, so some members that passed without links in G1 will now need them.

For a typical beam you can expect 5 to 10% less shear resistance without shear reinforcement under G2, so some members that passed without links in G1 will now need them.

Depth. G2 compared with G1 (\rho_l = 0.90%, D_{lower} = 16 mm): +16% at d = 150 mm, −9% at 350 mm, −13% at 500 mm, −19% at 800 mm and −22% at 1000 mm. The d_{dg}/d size effect is stronger than k for deep members, so check them first. Above d = 500 mm, minimum shear reinforcement is also mandatory in statically determinate linear members.

Reinforcement ratio. G2 compared with G1 (d = 350 mm, D_{lower} = 16 mm): +24% at \rho_l = 0.3% and +5% at 0.5%, where the new minimum governs. From \rho_l = 0.9% up to the 2% cap of G1 the difference is −9%, and it is +4% at \rho_l = 3%, where the G1 cap applies. Slabs and lightly reinforced members can therefore come out better than before.

Aggregate. D_{lower} is now a calculation input. In our example D_{lower} = 20 mm gives 58.9 kN (−5.7% compared with G1) and D_{lower} = 32 mm (d_{dg} = 40 mm, the cap) gives 61.0 kN (−2.3%). State the aggregate size in the concrete specification and keep it consistent with the calculation.

  • Steel grade: \tau_{Rdc,min} contains f_{yd}, so a higher steel grade lowers the minimum slightly.
  • Loads near supports: check the shear span a_{cs} = M_{Ed}/V_{Ed}. When it is below 4d, G2 replaces d by a_v, which is a different route from the G1 reduction \beta.
  • National Annex: \gamma_V = 1.4 is an NDP value, so check your National Annex before using the numbers in this article for a project.

Try it in Diamonds

Diamonds is BuildSoft’s 3D FEM structural analysis software, and you can learn it in under an hour. Start your free 30-day trial at buildsoft.eu.

Sources

Sources: EN 1992-1-1:2004, 6.2.1, 6.2.2 and 9.2.2; EN 1992-1-1:2023, Table 4.3, 8.2.1 and 8.2.2.