Eurocode 2 second generation (G2): what changes for structural engineers

At a glance

The new Eurocode 2, the second generation of EN 1992-1-1, replaces the 2004 version, and CEN plans to withdraw the first generation by 30 March 2028. This series compares the old and new rules one topic at a time, with the same worked example in every article: a C25/30 rectangular section of 300×400 mm. It is written for structural engineers who design concrete structures and want to know what changes in their calculations.

Not a complete list: this series does not cover every change between G1 and G2. It selects the changes that matter most for structural analysis and design, and leaves the rest to the standard itself.

G1 and G2 explained

Short nameStandardStatus
G1EN 1992-1-1:2004, the first generation The code you design with today
G2EN 1992-1-1:2023, the second generationCan only be applied in a country once its National Annex is published

G1 and G2 are shorthand for this series. CEN itself speaks of first and second generation Eurocodes. Clause numbers change as well as the rules: shear without shear reinforcement is 6.2.2 in G1 and 8.2.2 in G2, so every article gives both references.

When the new Eurocode 2 applies

CEN/TC 250 set three dates in its timeline letter of 21 September 2023:

DateMilestoneWhat it means
30 March 2026 at the latestDate of availability (DAV)Final texts reach the national standards bodies
30 September 2027Date of publication (DoP)Latest date for each country to publish the standard nationally
30 March 2028Date of withdrawal (DoW)Conflicting national standards, including the first generation, must be withdrawn

Countries may publish earlier: Ireland expects to adopt all second generation parts by the end of Q1 2027. In Belgium, Buildwise notes that EN 1992-1-1:2023 does not yet have the status of a Belgian standard and can only be applied once the Belgian National Annex is published. Check the current status with your national standards body before you start a project under G2.

The 11 topics in this series

We start with the points that change a calculation result or a detail on site:

#TopicG1 → G2 clause
1Concrete stiffness E_cm3.1.3 → 5.1.4
2Design strength and stress-strain diagram3.1.6–3.1.7, 6.1 → 5.1.6, 8.1.2
3Creep and shrinkage3.1.4, Annex B → 5.1.5, Annex B
4Durability and concrete cover4.4 → 6.3–6.5
5Shear without shear reinforcement6.2.2 → 8.2.2
6Shear with shear reinforcement6.2.3 → 8.2.3
7Torsion6.3 → 8.3
8Punching shear6.4 → 8.4
9Crack control7.3 → 9.2
10Deflection control7.4 → 9.3
11Anchorage and laps8.4, 8.7 → 11.4, 11.5

How each article is built

Every article has the same four parts, so you can find what you need quickly:

  1. At a glance: the difference in one or two sentences, with its size in percent.
  2. G1 vs G2 side by side: the rules with clause numbers, one symbol per row.
  3. Worked example: the same C25/30, 300×400 mm section in both codes, so results are comparable across articles.
  4. What it means in practice: the effect on deflections, reinforcement or detailing.

Sources and disclaimer

Timeline and status as read on 9 November 2026: the CEN/TC 250 timeline letter. Rules and figures follow EN 1992-1-1:2004 and EN 1992-1-1:2023. National Annexes may set different values, so check your country’s annex before using a figure in a design.

This series is not a complete list of the changes between EN 1992-1-1:2004 and EN 1992-1-1:2023. It covers the most important ones for structural analysis and design. For the full requirements, always refer to the standard and your National Annex.